Pipe Friction Loss Calculator

Calculate pressure drop and head loss in pipes using the Hazen-Williams equation. Includes equivalent length method for fittings and valves.

Fittings

0.20
Total Head Loss (ft)
0.09
Pressure Drop (PSI)
9.56
Velocity (ft/s)
0.147
ft loss / 100 ft

Calculation Breakdown

Straight Pipe Loss

0.15 ft

Fitting Equivalent Length

39.3 ft

Fitting Head Loss

0.06 ft

Flow Regime

Turbulent

✅ Velocity within recommended range (2-10 ft/s)